keyword : Product Category :
  • Name: ALC6000 smart RF capacitive level transmitter
  • Views : 131

Product introduction

1.Measurement mechanism

ALC6000 transmitter series are used in continuous measurement of RF capacitive material level. This capacitive level transmitter is widely applied almost all kinds of industry. Measurement detector and vessel make up a capacitor. The change of material level could produce the change of capacitive., the change of capacitive could analyze for handling and then transform a level signal.

Main feature:

1.Strong adaptability: the product could reliablely work under the formidable inviroment, such as high temperature, strong corrosion, strong adhesion, large dust etc.

2.The indication s of position is simple.

3.No need to maintenance: because of simple sensor structure and without movable part, the product no need to maintenance as it work.

The component of product

1.process connection and detector.

2.shell+4-20mA HART intelligent board

3.the introduction of measurement detector

 

    The company offer many kinds of detectors which apply for continuous level transmitter. In spite of the measurement technology is same, but different detector design is suitable to different application.

    For the choice of RF capacitive level is effected by many elements, such as electric, chemical, machanical.

The electric element: needing to offer earthing referred electrode such as the metal container skin, steel bar of reinforce concrete. The distance of the detector(main electrode) and earth electrode(referred electrode) could not surpass 200mm, if the distance surpass, please add assistant electrode or apply bipolar electrode detector. The medium with low viscocity and low dielectric should add coaxial . And the medium with high viscocity and low dielectric should apply bipolar electrode.

    The chemical element: the material of the detector must be compatible with the process medium,and could not be rusty by the corrosion medium, and at the same time having no pollution for the medium.

    The machancial element: the detector should bear the highest pressure and highest temperature of application site. In addition, stirring, thickness,viscosity,abrasion and installation configuration also affect the choice of detector. If the length of detector surpass 6m or space limit need to choose the lithe cable and avoid to apply rigid bar.

 

 

 

specification

ALC-6000A

ALC-6000B

ALC-6000C

ALC-6000D

Shape

Detector shape

Absolute insulation and single bar (could be with coaxial reference electrode)

 

 

 

Absolute insulation and single cable

Absolute insulation and double bar

Absolute insulation and double cables

Application range

Liquid:special recommending fo r the conduction liquid such as water-base liquid,acid-base salt liquid.etc.

Liquid:special recommending fo r the conduction liquid such as water-base liquid,acid-base salt liquid.etc.

Installation space or measurement range is above 6m

Liquid,specially recommending the medium with strong acid, strong basicity or

low dielectric constant or the situation which could not offer the reference electrode

Liquid,specially recommending the constant medium with strong acid, strong basicity or

low dielectric or the situation which could not offer the reference electrode.

Installation space limit or measurement range is above 6m

Installation requirement

Recommending to use the reference electrode which is equal or above main electrode length, such as metal container skin,installation tube etc. the consumers can add to install the reference electrode which is equal to or above the main electrode.

Recommending to use the reference electrode which is equal or above main electrode length, such as metal container skin,installation tube etc. the consumers can add to install the reference electrode which is equal to or above the main electrode.

The situation need not to offer the reference electrode.

The situation need not to offer the reference electrode.

Measurement range(detector length)

10-6000mm

0.5m-35m

10-6000mm

0.5-35m

Insulation material

PTFE

PTFE

PTFE

PTFE

Process connector

Standard NPT1, the the screw thread over G3/4 could be choice; also over DN20 flange, over1inch sanitary lathedog or locknut connector

Standard NPT1, the the screw thread over G1 could be choice; also over DN40 flange, over1.5 inch sanitary lathedog or locknut connector

Above DN50 flange

Above DN50 flange

Process temperature

-184ºC`240ºC

-184ºC`240ºC

-184ºC`240ºC

-184ºC`240ºC

Process pressure

-0.1-7Mpa

-0.1-7Mpa

-0.1-7Mpa

-0.1-7Mpa

 

specification

ALC-6000A

ALC-6000B

ALC-6000C

ALC-6000D

shape

Detector shape

Partial insulation and single bar

(could be with coaxial reference electrode)

Partial insulation and single cable

Partial insulation and double cables

Partial insulation

double cables with high temperature bar

Application range

Solid particle,mealiness material, non-thickness with low dielectrical liquid is suggested to add coaxial electrode

Solid particle,mealiness material, no-conductive liquid

Solid particle,mealiness material, no-conductive liquid, the installation space limit or measurement range is above 6m applies the cable detector

Solid particle,mealiness material, no-conductive liquid, the installation space limit or measurement range is above 6m applies the cable detector

Installation requirement

Recommending to use the reference electrode which is equal or above main electrode length, such as metal container skin,installation tube etc. the consumers can add to install the reference electrode which is equal to or above the main electrode.

Recommending to use the reference electrode which is equal or above main electrode length, such as metal container skin,installation tube etc. the consumers can add to install the reference electrode which is equal to or above the main electrode.

The situation need not to offer the reference electrode.

Recommending to use the reference electrode which is equal or above main electrode length, such as metal container skin,installation tube etc. the consumers can add to install the reference electrode which is equal to or above the main electrode.

Measurement range(detector range)

10-6000mm

0.5-35m

Bar type:100-6000mm

Cable type:0.5m`35m

Bar type:210-6000mm

Cable type:0.5m-35m

Insulation material

PTFE

PTFE

PTFE

Ceramics

Process connector

 

Standard NPT1, the the screw thread over G1 could be choice; also over DN40 flange, over1.5 inch sanitary lathedog or locknut connector

Above DN50flange

Above G11/2 screw thread,

Above DN50 flange.

Process temperature

Standard NPT1, the the screw thread over G3/4 could be choice; also over DN20 flange, over1inch sanitary lathedog or locknut connector

-184ºC`240ºC

-184ºC`240ºC

-50ºC`450ºC

Process pressure

-184ºC`240ºC

-0.1-7Mpa

-0.1-7Mpa

-0.1-7Mpa

 Installation Guide

You must consider the activity space offered by the installation point could install the transmitter or not, and this matter should consider before you choose the detector and order the product.

If the space is limited when you choose bar detector, you should consider to choose the lithe cable detector, and also consider the size of electronic parts and shell. If the flange is used, you should consider to add additional height for installing and unloading the flange and shell.

 Installation position

  If the single detector with using the metal container as reference electrode,and the also if the measurement subject is non-conductive medium,you must consider to install the detector near the container skin places(recommending distance is 150mm-200mm), and ensure the bars parallel with the container skin. Because under this condition the parallelism affect the linearity. If you don’t have these conditions, our company suggest you to apply double detector. When measuring conductive medium, the absolute single detector is alternative which could install any places against the metal container and no need to consider the electrode to keep parallel. Referred picture 4.1and picture4.2.

Single detector(partial insulation and absolute insulation)metal container

Measuring non-conductive process medium

The distance between the detector and container skin affects the measuring sensitivity.

The parallelism between the detector and container skin  affect the measuring linearity.

Single detector(must use the absolute insulation) metal container

Electric conduction process medium

The place of the detector against the container skin is not important.

And the parallel of the container skin(spheric container,horizontal container) all don’t affect the measurement.

Double-detectorscome with reference electrode, usually could be installed to any places of container skin and no need to consider measuring material which is conductive or not. Referring to picture 3,4.

  Pay attention to that you should not install the detector which is near the equipment such as obstacle,stirrer and heater etc.. This point is very import for the measuring non-conductive medium. Measuring the conductive medium only produce very little physical error.

  Regardless the measuring material is conductive or non-conductive, please try your best to install the detector on the stable and representative position. If installing positon near the flow or spray, it could produce man-made and high material positon reading. And installing the detector near the stirrer which could cause swirl which could give a man-made low position reading.

Reference electrode

Under the normal condition, double detectors(carried reference elecrode) are used in the non-metal condition. If single detector is applied for the reference electrode, it could be used in the same position. The reference electrode length could be equal to the detector bar, and the reference electrode is installed with the parallel of the detector. The distance is not above 150-200mm.

  The reference electrode must keep electric connection,and could directly connect with eath terminal,or through the screw thread of the detector, the shell of electronic shell directly connect. Under any condition,you should operate the step of eath “continuity detection” to make sure the earth connection.

  If the measuring medium is non-conductive, the non-parallelism of earth reference electrode and detector will affect the measuring linearity. At the same time, the distance between two electrode poles will add, which will reduce the response(sensitivity).

The electric performance index

Power supply voltage:9VD.c-32VD.C

Output signal: 4-20mA superimposing HART communication

Accuracy class:=/-0.5% F.S

Working temperature range:-20ºC(with backlight LCD );

-40 ºC-+85ºC(without LCD;

Be able to choose intrinsic safety;

Input capacitive range: 40PF-2500PF

Sensitivity:≤0.1pF

Display: with backlight and digital LCD; be able to display every kind of engineering unit

The maximum load: when DC24 supply power, 750Ω

Diagnostic tool: when the transmitter break down,the output alarm output the electric current.

Configuration function: zeroing; setting up unit, measuring range, damping,output property, changing display output,adjusting lower limit, adjusting upper limit.

Nearby adjusting function:be able to make use of two random material position to spot calibration.

Shell material: aluminum alloy

Protection class: IP67

Choosing type guide

ALC6000 smart RF capacitive level transmitter

ALC6000

Detector type:

A:absolute insulation singe bar

B: absolute insulation singe cable

C:absolute insulation double detector

D; absolute insulation double cable detector

E: partial insulation single bar

F: partial insulation double cable

E:partial insulation cable detector with double bars

F: partial insulation cable detector with high temperature bar

Certification:

P standard type

E flame proof type

I intrinsic type

Process connection

N1 NPT1” vertebral screw

G1  G1 crew thread

F1 DN50PN2MPa flange

F2 DN80PN2MPa flange

T1 1” lathedog(Tri-Clamp)

T21.5 lathedog(Tri-Clamp)

N please note your special requirement

Process connection material

A 304 stainless steel

B 316 stainless steel

C  PTFE

N  other special material

Detector length(L)mm

 